Altinex Camcorder DA1907SX User Manual

DISTRIBUTION AMPLIFIER  
MANUAL PART NUMBER: 400-0045-005  
DA1907SX  
1-IN, 2-OUT VGA/SVGA/XGA/UXGA  
DISTRIBUTION AMPLIFIER  
USER’S GUIDE  
DISTRIBUTION AMPLIFIER  
PRECAUTIONS / SAFETY WARNINGS  
1
·
Do not pull the power cord of AC Adapter or any  
cable that is attached to the DA1907SX  
Distribution Amplifier.  
Please read this manual carefully before using your  
DA1907SX Distribution Amplifier. Keep this manual  
handy for future reference. These safety  
instructions are to ensure the long life of your  
DA1907SX and to prevent fire and shock hazard.  
Please read them carefully and heed all warnings.  
·
If the DA1907SX Distribution Amplifier is not  
used for an extended period, disconnect the  
Power (AC) Adapter from the power outlet.  
1.4 CLEANING  
1.1 GENERAL  
·
Unplug the DA1907SX AC Adapter from the wall  
before cleaning. Clean surfaces with a dry cloth.  
Never use strong detergents or solvents, such  
as alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
·
·
Unauthorized personnel shall not open the unit  
since there are high-voltage components inside.  
Qualified Altinex service personnel, or their  
authorized representatives, must perform all  
service.  
1.5 FCC / CE NOTICE  
·
·
This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
1.2 GUIDELINES FOR RACK-MOUNTING  
·
·
Maximum operating ambient temperature is  
45ºC.  
Distribute rack-mount units evenly; otherwise,  
hazardous conditions may be created by an  
uneven weight distribution.  
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
·
Reliable grounding of rack-mounted Equipment  
should be maintained.  
1.3 INSTALLATION  
·
For best results, place the DA1907SX  
Distribution Amplifier on a flat, level surface in a  
dry area away from dust and moisture.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and, if  
not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at their expense.  
·
To prevent fire or shock, do not expose this unit  
to rain or moisture. Do not place the DA1907SX  
Distribution Amplifier in direct sunlight, near  
heaters or heat radiating appliances, or near any  
liquid. Exposure to direct sunlight, smoke, or  
steam can harm internal components.  
·
·
Handle the DA1907SX Distribution Amplifier  
carefully. Dropping or jarring can damage  
internal components.  
·
Any changes or modifications to the unit not  
expressly approved by Altinex, Inc. could void  
the user’s authority to operate the equipment.  
Do not place heavy objects on top of the  
DA1907SX. If the DA1907SX is to be mounted  
to a table or wall, use only Altinex made  
mounting accessories.  
·
The power outlet socket should be installed as  
close to the as possible, and should be easily  
accessible.  
400-0045-005  
2
DISTRIBUTION AMPLIFIER  
ABOUT YOUR DA1907SX  
2
MECHANICAL  
DA1907SX  
Material  
Finish  
Top Panel  
0.1” Al  
Gray  
Lexan  
The DA1907SX (Ditto-Amp) is a high-resolution,  
1-in 2-out distribution amplifier designed to allow  
the connection of a single VGA/SVGA/XGA/UXGA  
source to up to two scan-rate compatible displays.  
A minimum video bandwidth of 400 MHz allows  
very high-resolution video signals to pass without  
degradation to the image quality. The Local Monitor  
Output of the DA1907SX is pre-compensated for  
up to 12 feet of high-resolution coaxial-type VGA  
cable. The Main Output of the DA1907SX is pre-  
compensated for up to 250 feet with high-resolution  
coaxial-type VGA cable.  
Height (inches)  
Width (inches)  
Depth (inches)  
Weight (pounds)  
Ship Weight (pounds)  
T° Operating  
T° Maximum  
Humidity  
3.00in (76mm)  
4.50in (114mm)  
1.00in (25mm)  
0.40lb (0.18kg)  
2.4lbs (1.09kg)  
10°C-35°C  
45°C  
90% non-condensing  
MTBF (calculations)  
40,000 hrs  
Table 2. DA1907SX Mechanical  
Being compact and easy to use, the DA1907SX is  
perfect for audio/visual installations, where a single  
computer needs to be connected to a projector (or  
ELECTRICAL  
DA1907SX  
Input Video Signal  
Analog Signal Level  
Impedance  
Input Sync Signal  
Horizontal, Vertical, & C-Sync  
Sync on Green  
presentation monitor) and  
a
local monitor  
1.5V p-p max  
75 Ohms  
simultaneously. The DA1907SX has female 15-pin  
HD (VGA type) connectors on all input and output  
connectors so it can be used with readily available  
standard VGA type cables. If desired, the input  
and/or output of the DA1907SX can be easily  
adapted to 5 BNC connectors through Altinex  
adapter cables.  
TTL(+/-)  
-0.3V  
10 k Ohms  
Impedance  
Output Video Signals  
Analog Signal Level  
Fall/Rise Time (ns)  
Impedance  
Output Sync Signals  
Composite Sync  
Sync on Green  
Gain of 1.05 (+/-5%)  
1.0  
75 Ohms  
The DA1907SX is compatible with RGsB, RGBS,  
or RGBHV signal types and with the proper cable  
the DA1907SX can be used with MAC, SUN or SGI  
platform computers.  
TTL(+/-)  
-0.3V  
Impedance  
22 Ohms  
TECHNICAL SPECIFICATIONS  
3
Frequency Compatibility  
Typical Video Bandwidth  
Minimum Video Bandwidth  
Horizontal  
Vertical  
Cable EQ at Main Output  
Coupling  
FEATURES/DESCRIPTION  
GENERAL  
Inputs  
Input Connector  
Outputs  
Local Monitor Connector  
Main Output Connectors  
Compatibility  
DA1907SX  
430 MHz @ -3 dB  
400 MHz @ -3 dB  
15-200 kHz  
47-180 Hz  
3 dB @ 120 MHz  
DC  
One  
15-pin HD Female  
Two  
15-pin HD Female  
15-pin HD Female  
VGA, SVGA, XGA,  
UXGA, MAC, SUN,  
SGI  
Cross-talk  
Power, External  
-40 dB @ 10 MHz  
9V DC, 500 Ma  
Table 3. DA1907SX Electrical  
Table 1. DA1907SX General  
400-0045-005  
3
DISTRIBUTION AMPLIFIER  
Pin  
1
2
Main Outputs  
Red  
DESCRIPTION OF DA1907SX  
4.1 INPUT  
4
Green  
The Computer Input connector of the DA1907SX is  
connected to the Video output of a laptop or  
desktop computer. The DA1907SX is provided with  
a 3 foot Male to Male VGA Input cable. A longer  
input cable may be used but lengths over 15 feet  
are generally not recommended to preserve the  
signal quality. If desired, the HD-15 input can be  
easily adapted to a 5-BNC connector output with  
the proper cable.  
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Blue  
No connection  
Ground  
Ground  
Ground  
Ground  
Composite Sync  
No connection  
No connection  
No connection  
Horizontal Sync  
Vertical Sync  
Ground  
Pin  
1
Inputs  
Red  
Green  
Blue  
2
3
ID Bit 4 (Grounded, when  
ID Bit 4 switch is ON)  
Ground  
Ground  
Ground  
Ground  
No connection  
ID Bit 3  
ID Bit 1  
ID Bit 2  
Table 5. Main Outputs  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
Pin  
1
2
3
4
5
6
7
8
Local Output  
Red  
Green  
Blue  
ID Bit 4  
Ground  
Ground  
Ground  
Ground  
Horizontal Sync  
Vertical Sync  
No connection  
9
Composite Sync  
Table 4. Computer Input  
10 ID Bit 3  
11 ID Bit 1  
12 ID Bit 2  
4.2 OUTPUTS  
The DA1907SX has two buffered outputs with  
15-pin HD Female connectors. The Local Monitor  
output is an amplified output. The Main output is for  
the distant presentation display (large screen  
monitor or LCD projector) up to 250 feet away. The  
Main output is pre-compensated for optimal  
performance with 75 ft of Altinex super  
high-resolution VGA cable. If desired the outputs  
can be adapted easily to 5-BNC connectors with  
the proper cable.  
13 Horizontal Sync  
14 Vertical Sync  
15 No connection  
Table 6. Local Monitor Outputs  
400-0045-005  
4
DISTRIBUTION AMPLIFIER  
PRODUCT DESCRIPTION  
VGA COMPUTER  
VIDEO INPUT  
VGA  
MAIN  
OUT  
POWER  
INPUT  
VGA MONITOR  
LOCAL OUTPUT  
APPLICATION DIAGRAM  
DIAGRAM 1: TYPICAL SETUP  
5
400-0045-005  
5
DISTRIBUTION AMPLIFIER  
INSTALLING YOUR DA1907SX  
6
OPERATION  
7
Step 1. Connect the 9V 500mA AC adapter’s  
output plug to the DA1907SX’s power  
input connector - 2.5 mm DC Jack. Verify  
the LED in the top right corner of the unit  
on the front panel turn on and RED.  
There are no adjustments necessary to operate the  
DA1907SX, the unit will operate successfully as  
long as cables are attached properly and other  
technical specifications are followed.  
The DA1907SX offers a special LED on the front  
panel that provides feedback to the user. When  
power is connected to the DA1907SX, the LED will  
turn RED. The LED will turn GREEN when an  
active computer source is connected. This indicates  
that it is receiving a proper signal by sensing the  
presence of the sync portion of that signal.  
Step 2. Remove the protective port covers.  
Connect the video output from the  
computer to the computer input connector  
on the DA1907SX using the provided  
input VGA cable. If a longer cable is  
required, please make sure that the cable  
has video signals through coaxial cables  
and this cable is not excessively long.  
TROUBLESHOOTING  
8
We have carefully tested and have found no  
problems in the supplied DA1907SX; however, we  
would like to offer suggestions for the following:  
Step 3. Verify the LED on the face of the unit has  
changes from RED to GREEN, indicating  
an active source is applied. If the LED is  
not green, the computer may not be  
8.1 LED IS NOT RED  
sending video signals.  
Check your  
The LED should be ON and RED when power is  
applied and there is no video signal present. If  
the LED is ON and GREEN, the unit is receiving  
power and a SYNC signal.  
Computer’s manual if you are using a  
laptop computer. You may have to send a  
command that instructs the laptop to  
output to the internal display and the  
external video port simultaneously.  
Cause 1: No AC power.  
Solution: Verify the Altinex supplied adapter is  
plugged into a working AC outlet  
and that the outlet has power.  
Step 4. Connect your display device (monitor or  
projector) to the Main output. If needed,  
connect a monitor to the Local Monitor  
output port.  
Cause 2: Adapter is not plugged.  
Solution: Verify the DC power plug coming  
from the AC adapter is plugged all  
the way into the DA1907SX.  
Step 5. Verify the picture quality on all displays is  
good. If you are not receiving a signal,  
make sure that the display is compatible  
with the resolution of the computer  
graphics card. Note: High levels of static  
discharge under some conditions may  
shutdown the unit. To reset the unit  
simply, disconnect the input cable and  
reconnect it.  
Cause 3: The DA1907SX has a problem.  
Solution: If there is AC power to the adapter  
and the LED still does not turn on,  
the DA1907SX or the power adapter  
may require service. Call ALTINEX  
at (714) 990-2300.  
400-0045-005  
6
DISTRIBUTION AMPLIFIER  
8.2 LED IS NOT GREEN  
Cause 2 Poor signal transmission.  
Cause 1: There is no power.  
Solution: Check the cables for continuity and  
make sure that connections are  
wired properly. If the image is still  
not correct, see Cause 3.  
Solution: Disconnect the video input from the  
DA1907SX and verify the LED is ON  
and RED indicating power is  
present. Reconnect the computer's  
video output. If the LED is still not  
GREEN see Cause 2.  
Cause 3: Cable runs too long.  
Solution: Make sure that the outputs are  
terminated properly and the cable  
run does not exceed 15 feet for the  
local monitor output and 100 feet for  
the main output port.  
Cause 2: There is no Sync signal.  
Solution: Verify the computer output is  
operating correctly by connecting it  
directly to a local monitor. If the  
display is good, call ALTINEX at  
(714) 990-2300.  
NOTE: The DA1907SX is capable of  
driving a computer video signal up to  
250 feet depending on the resolution  
and cable quality.  
8.3 NO REMOTE IMAGE  
8.4 CONSTANT USAGE ERRORS  
Cause 1: The source has a problem.  
Cause 1: There is an environment problem.  
Solution: Check the image on a local monitor  
and verify the quality is good. If the  
local image is good, see Cause 2.  
Solution: If a problem arises after continuous  
usage at higher voltage, higher  
temperature, higher humidity, or at  
Cause 2: Cable connections are incorrect.  
other  
extreme  
environmental  
Solution: Make sure that cables are  
connected properly. Also, make sure  
that the continuity and wiring are  
good. If there is still no image  
present, see Cause 3. If the display  
is good, call ALTINEX at (714)  
990-2300.  
conditions, please correct the  
problem,  
(714) 990-2300.  
or  
call  
Altinex  
at  
9
ALTINEX POLICY  
9.1 LIMITED WARRANTY/RETURN POLICY  
Please see the Altinex website  
at  
Cause 3: Signals are bad.  
www.altinex.com for details on warranty and  
return policy.  
Solution: Make sure that the amplitude of the  
input video analog signal is less than  
1.5V and the SYNC input is at a TTL  
level.  
9.2 CONTACT INFORMATION  
ALTINEX, INC  
8.4 REMOTE IMAGE QUALITY IS POOR  
Cause 1: The source has a problem.  
592 Apollo Street  
Brea, CA 92821 USA  
TEL: 714 990-2300  
Solution: Check the image on the local  
monitor and verify the quality is  
good. If the local image is good, see  
Cause 2.  
TOLL FREE: 1-800-ALTINEX  
400-0045-005  
7

Bodum Blender K11179 User Manual
Canon MV730i User Manual
Canon PC428 Personal Copier 7239A023AA User Manual
Canon XL1 User Manual
Crown Audio Car Speaker 180MAx User Manual
DB Performance AWD Dyno Tuning Car Speaker K312D4 User Manual
Dual XC4100 User Manual
Elinchrom BX 500RI User Manual
Hitachi HV F31F User Manual
JVC GR DF473 User Manual